CYGNUS INSTRUMENTS – Cygnus 6+ PRO Mk5 UTG Kit, without Probe
050-6500/5
The Cygnus 6+ UT thickness gage boasts a full suite of features for the demanding professional user, including: A-scan; B-scan; full data recording capability; 3 distinct measuring modes; high temperature transducer and manual gain control.
PROBE NOT INCLUDED – YOU MUST PURCHASE A PROBE AND
PROBE LEAD WITH THIS GAUGE. STANDARD PROBE IS 004-9500 WITH PROBE LEAD 004-0410
Key Features of the Cygnus 6+ PRO Meter
- Multiple-Echo mode for accurate, through-coat measurements as specified by Classification Societies
- Echo-Echo and Single-Echo modes for heavily corroded metals with thin (or no) coatings
- Temperature Compensation
- Deep Coat function ignores coatings up to 0.8 inch thick
- Manual and automatic gain control
- Min/max measurement limit functions with visual and vibrate alert
- Uses both single and twin crystal transducers
- One and two point calibration
- Freeze function
- Bluetooth™ for data transfer
- Large front LCD display and an end-mounted LCD display with grayscale setting for bright sunlight
- Safe operation in explosive atmospheres: Class 1, Division 2, Group D locations only, as defined in NFPA 70, Article 500
- Water and dust tight IP67 housing
- Shock and impact proof to US MIL STD 810G.
High Temperature Measurement
Using the T5B-MAUH high temperature transducer, measurements can be taken on hot surfaces of up to 572°F.
No cooling period is required – which can reduce inspection time and facilitate more effective measurement.
Optional upgrade to braided cable.
Comprehensive Data Logging
- Linear, 2D grid and template data recording options
- 16 grid patterns available
- ‘Radial points’ can be added to any measurement to further investigate an area of interest or heavy corrosion
- Auto-log feature
- Saves measurements and corresponding wave forms / A-scans
- Eight user-defined text comments to attach to any measurement point
- Records stored on an SD card
- Dedicated CygLink software used to transfer and manage data.
Three Versatile Measuring Modes
- Multiple-Echo mode uses three error checked back wall echoes to provide the most reliable and accurate remaining thickness measurements possible, with no need to remove coatings up to 0.8 inch thick
- Single-Echo mode is ideal for measuring uncoated metals with heavy front and/or back-wall corrosion. Also effective on a range of cast metals, plastics and composites
- Echo-Echo mode works best for measuring heavily corroded metals through thin coatings of up to 0.04 inch thick, ideal for measuring painted metals with heavy back wall corrosion.
CygLink Computer Software
CygLink is a Windows® based application used to both transfer and manage data logged records, their corresponding A-scans as well as measurement comments and material velocity tables. The program can generate PDF reports to present to a client and will also export data to Excel. Cyglink also displays A‑scans, allowing for after-the-event and off-site analysis of logged measurements.
The latest version of CygLink software is available to download – from ‘Software Downloads’.
Measurement Stability Indicator (MSI™)
Exclusive to Cygnus, MSI™ ensures stable and therefore reliable measurements are displayed in Echo‑Echo and Single-Echo modes.
Measuring Modes | Multiple-Echo using 3 echoes to ignore coatings up to 0.8 inch thick Echo-Echo using 2 echoes to ignore coatings up to 0.04 inch thick Single-Echo using 1 echo |
Materials | Velocities from 0.0390 – 0.3543 in/us |
Accuracy | ±0.002 inch – in Multiple-Echo measurement mode, when calibrated and measuring the same material as calibrated on ±0.004 inch or 0.1% of thickness measurement whichever is the greatest – in Single-Echo & Echo-Echo measurement modes, when calibrated and measuring the same material as calibrated on |
Resolution | Multiple-Echo mode – 0.005 inch or 0.002 inch Single-Echo and Echo-Echo modes – 0.005 inch or 0.001 inch |
Transducer options | Single crystal transducers, Twin crystal transducers and High temperature transducer |
Measurement Range in Steel | 0.031 – 10 inch depending on selected transducer and configuration, material and temperature |
Connector | 2 x Lemo 00 |
Power | 3 x AA / R6 batteries |
Battery Life | Approx. 10 hours continuous measurement |
Electronics | Dual channel pulser |
Display | Front LCD 2.4 inch QVGA: 47 x 37 mm End-mounted LCD: 25.58 x 6.38 mm |
Size | 3.3 x 5.1 x 1.4 inch |
Weight | 10.5 oz (inc. batteries) |
Operating Temp. | 14°F to 122°F |
Data Logging | 5,000 measurements and A-scans per record Max number records: 100 (soft limit) |
Computer Software | CygLink allows remote logging and viewing of A-scan graphs Survey and report generation to PDF file Graphic analysis of data and statistical calculations |
Environmental Rating | IP67 Safe operation in Explosive Atmospheres: Class I, Division 2, Group D Locations only, as defined in the National Fire Protection Association Code (NFPA 70), Article 500. Tested using MIL-STD-810G, Method 511.5, Procedure I MIL STD 810G Method 501.6 (high temp +55°C) MIL STD 810G Method 502.6 (low temp -20°C) MIL STD 810G Method 507.6 (humidity 95%) MIL STD 810G Method 512.6 (immersion 1 metre for 30 mins) |
Shock and Impact | MIL STD 810G Method 514.7 (vibration) MIL STD 810G Method 516.7 (shock 20g) MIL STD 810G Method 516.7 (transit drop 1.22 m) |
Standards | Designed for EN 15317 |
Compliance | CE, UKCA, RoHS |
Warranty | 3 years on gage and 6 months on transducer |