HASKEL Booster – AGD O2 Clean – Single Stage/Double Action (AGD-15-O2)
Double Acting, Single Stage “AGD” boosters not only pump twice the volume of a Single Acting, Single Stage Booster per cycle, but also require less air drive since the inlet gas pressure is assisting the air drive in each direction, providing a substantial portion of the required driving force. These models provide efficient means of boosting large volumes of gas at low to medium compression ratios.
SKU | Maximum Rated Gas Supply |
Minimum Gas Supply Pressure |
Maximum Rated Gas Outlet: psi (bar) |
Static Stall Pressure |
Piston Displacement Per Cycle |
Gas Inlet/Outlet |
Weight | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
Model | psi | bar | psi | bar | Inert Gas | Oxygen | Formula† | cu in | ML | Connections | lb (kg) |
AGD-15-O2‡ | 5000 | 345 | 50 | 3.5 | 5000 (345) |
5000 (345) |
15 Pa+Ps | 12.4 | 203.2 | ** | 35 (16) |
‡ The AGD-15-O2, AGD-30-O2, and AGD-32-O2 boosters are “oxygen service” ready equipment. Boosters are not oxygen service ready unless otherwise noted.
**Interchangeable 3-3/8 in SAE or 1/4 in – H/P both ports. 2 each: inlet & outlet.
Flow and Pressure Performance: Double Acting, Single Stage AGD Booster Series
PA = 90 psi
Sample performance shown below is used for general reference only
AGD-15-O2‡ | Qa
40 |
Ps
2100 |
Po
3000 |
Q
50.3 |
LEGEND
Pa = Air Drive Pressure
Ps = Gas Supply Pressure
Qa = Air Drive Quantity
Po = Gas Outlet Pressure
Q = Gas Outlet Flow Rate