Thank you for your continued support this year. Please note that we’ll be short-staffed during the holiday season, but we’ll do our best to respond to emails as quickly as possible. Our office will be closed from December 23 to January 3, resuming normal operations on January 6. Wishing you a joyful holiday season and a prosperous New Year!

HASKEL Booster – AGD O2 Clean – Single Stage/Double Action (AGD-15-O2)

USD $9,463.00

SKU: AGD-15-O2 Category: Tags: ,

HASKEL Booster – AGD O2 Clean – Single Stage/Double Action (AGD-15-O2)

Double Acting, Single Stage “AGD” boosters not only pump twice the volume of a Single Acting, Single Stage Booster per cycle, but also require less air drive since the inlet gas pressure is assisting the air drive in each direction, providing a substantial portion of the required driving force. These models provide efficient means of boosting large volumes of gas at low to medium compression ratios.

HASKEL Booster – AGD O2 Clean – Single Stage/Double Action (AGD-15-O2)

Double Acting, Single Stage “AGD” boosters not only pump twice the volume of a Single Acting, Single Stage Booster per cycle, but also require less air drive since the inlet gas pressure is assisting the air drive in each direction, providing a substantial portion of the required driving force. These models provide efficient means of boosting large volumes of gas at low to medium compression ratios.

SKU Maximum Rated
Gas Supply
Minimum Gas
Supply Pressure
Maximum Rated Gas
Outlet: psi (bar)
Static Stall
Pressure
Piston Displacement
Per Cycle
Gas
Inlet/Outlet
Weight
Model psi bar psi bar Inert Gas Oxygen Formula cu in ML Connections lb (kg)
AGD-15-O2 5000 345 50 3.5 5000
(345)
5000
(345)
15 Pa+Ps 12.4 203.2 ** 35 (16)

 The AGD-15-O2, AGD-30-O2, and AGD-32-O2 boosters are “oxygen service” ready equipment. Boosters are not oxygen service ready unless otherwise noted.

**Interchangeable 3-3/8 in SAE or 1/4 in – H/P both ports. 2 each: inlet & outlet.

 

Flow and Pressure Performance: Double Acting, Single Stage AGD Booster Series

PA = 90 psi

Sample performance shown below is used for general reference only

AGD-15-O2 Qa

40
40
40
40

Ps

2100
1500
900
300

Po

3000
2400
1800
1200

Q

50.3
36.1
21.5
6.7

LEGEND
Pa = Air Drive Pressure
Ps = Gas Supply Pressure
Qa = Air Drive Quantity
Po = Gas Outlet Pressure
Q = Gas Outlet Flow Rate

Weight 37 lbs