Thank you for your continued support this year. Please note that we’ll be short-staffed during the holiday season, but we’ll do our best to respond to emails as quickly as possible. Our office will be closed from December 23 to January 3, resuming normal operations on January 6. Wishing you a joyful holiday season and a prosperous New Year!

NUVAIR – Replacement Sensor Oxygen O2 – 9510

145.00 CAD

Out of stock

NUVAIR – Replacement Sensor Oxygen O2 – 9510

The Nuvair 9510 replacement oxygen sensor is for use with the following gas analyzers: Nuvair O2 Quickstick, OMS 2, UBS O2 Stick, and Nuvair Pro Trimix. For use in Pro Trimix analyzers sold before 04/2013.

NUVAIR – Replacement Sensor Oxygen O2 – 9510

The Nuvair 9510 replacement oxygen sensor is for use with the following gas analyzers: Nuvair O2 Quickstick, OMS 2, UBS O2 Stick, and Nuvair Pro Trimix. For use in Pro Trimix analyzers sold before 04/2013.

The 9510 is a replacement electrochemical oxygen sensor for gas analyzers. Under normal use, oxygen sensors have an expected service life of 36 months. The 9510 replacement sensor fits the following analyzers:

  • Nuvair O2 Quickstick™
  • OMS O2
  • UBS O2 Stick
  • Nuvair Pro Trimix sold before 04/2013

PLEASE NOTE: Never expose gas sensors to pressure or you may cause damage and/or false readings. Damaged sensors will not provide accurate gas analysis. Inaccurate gas analysis can lead to serious personal injury or death. Most gas analyzers can be used to analyze a regulated gas sample flow, the contents of a gas cylinder, or the flow from a regulator. The flow rate of gas must equal 1-5 L/min. To produce this flow, a Flow Restrictor and Regulator may be required.

Specifications

Output 25±2 mV in air at 25°C/77°F, sea level
Electrical Connector Mating plug: Molex (PN 22-28-0021 or 22-28-3021 or 22-23-5024)
Range 0-100% Oxygen
Accuracy +/-1% of full scale at constant temperature and pressure (0-1 atm) when calibrated with 100% oxygen
Sensor Type Electrochemical
Expected Sensor Life 36 months in air at 25°C/77°F and 50% rh
Response Time <6 seconds for 90% of final value
Operating Temperature 32-104°F (0-40°C)
Storage Temperature 32-122°F (0-50°C)
Humidity 0-99% rh (non-condensing)
Weight 1 oz (28.3 g)
Application For diving cylinder oxygen verification and other forms of oxygen testing on the surface/above water. Not intended for underwater use.
Weight 0.25 lbs
Dimensions 4 × 4 × 2 in